ANSYS 3D T/E MODELS RELATED PUBLICATIONS
ANSYS 3D T/E MODELS BROCHURE
FIRST ATTEMPT TO BREAK THE 10 KWH/KG BARRIER USING A WIDE CELL DESIGN (as published)
5.90 MEG
HOW TO LIMIT THE HEAT LOSS OF ANODE STUBS AND CATHODE COLLECTOR BARS (as published)
3.33 MEG
EXTENDED ENERGY BALANCE FOR HALL-HÉROULT ELECTROLYSIS CELLS
763 KB
BREAKING THE 11 KWH PER KG BARRIER (as published)
8.38 MEG
VERY LOW ENERGY CONSUMPTION CELL DESIGNS THE CELL HEAT BALANCE CHALLENGE
2.85 MEG
DESIGNING CELLS FOR THE FUTURE -WIDER AND/OR EVEN HIGHER AMPERAGE?
480 KB
LOW ENERGY CONSUMPTION CELL DESIGNS INVOLVING COPPER INSERTS AND AN INNOVATIVE BUSBAR NETWORK LAYOUT
2.47 MEG
NEW BUSBAR NETWORK CONCEPTS TAKING ADVANTAGE OF COPPER COLLECTOR BARS TO REDUCE BUSBAR WEIGHT AND INCREASE CELL POWER EFFICIENCY
2.92 MEG
ON THE IMPORTANCE OF FIELD VALIDATION IN THE USE OF CELL THERMAL BALANCE MODELING TOOLS
1.63 MEG
INFLUENCE OF THE CATHODE SURFACE GEOMETRY ON THE METAL PAD CURRENT DENSITY
1.85 MEG
IN DEPTH ANALYSIS OF ENERGY-SAVING AND CURRENT EFFICIENCY IMPROVEMENT OF ALUMINUM REDUCTION CELLS
953 KB
ENERGY SAVING FROM A REDUCTION POT (as published)
675 KB
DEPTH ANALYSIS AND POTENTIALITY EXPLOITATION ON ENERGY-SAVING AND CONSUMPTION-REDUCTION OF ALUMINUM REDUCTION POT
1.59 MEG
MODELING CATHODE COOLING DUE TO POWER INTERRUPTION
499 KB
MODELLING CATHODE COOLING AFTER POWER SHUTDOWN (as published)
2.55 MEG
MODELLING CATHODE COOLING AFTER POWER SHUTDOWN (as submitted)
1.10 MEG
USING ANSYS AND CFX TO MODEL ALUMINIUM REDUCTION CELL SINCE 1984 AND BEYOND
2.67 MEG
RETROFIT OF A 500 KA CELL DESIGN INTO A 600 KA CELL DESIGN
BUSBAR SIZING MODELING TOOLS: COMPARING AN ANSYS
®
BASED 3D MODEL WITH THE VERSATILE 1D MODEL PART OF MHD-VALDIS
IMPACT OF USING SELECTIVE COLLECTOR BAR RODDING ON THE MHD STABILITY OF A 500 KA ALUMINIUM ELECTROLYSIS CELL
WEAKLY COUPLED THERMO-ELECTRIC AND MHD MATHEMATICAL MODELS OF AN ALUMINIUM ELECTROLYSIS CELL
THERMO-ELECTRIC DESIGN OF A 740 kA CELL, IS THERE A SIZE LIMIT?
ACCURATE ASSESSMENT OF THE HIRAKUD SMELTER ALUMINIUM REDUCTION CELL THERMAL BALANCE USING ONLY TEMPERATURE MEASUREMENTS
DEMONSTRATION THERMO-ELECTRIC AND MHD MODEL OF A 500 KA AL ELECTROLYSIS CELL: PART 2
DEMONSTRATION THERMO-ELECTRIC AND MHD MODEL OF A 500 KA AL ELECTROLYSIS CELL
INDIAN ALUMINIUM SMELTERS ROADMAP SELECTS MATHEMATICAL MODELING AS KEY STRATEGIC ACTIVITY
PERFORMING FAST TREND ANALYSIS ON CELL KEY DESIGN PARAMETERS
TOWARDS THE DEVELOPMENT OF A 3D FULL CELL AND EXTERNAL BUSBARS THERMO-ELECTRIC MODEL
USING MATHEMATICAL MODELS TO IMPROVE THE THERMAL BALANCE OF HALL-HÉROULT CELLS
USING ANSYS TO MODEL ALUMINUM REDUCTION CELL SINCE 1984 AND BEYOND
MODELING POWER MODULATION
COMPUTATION OF ACCURATE HORIZONTAL CURRENT DENSITY IN METAL PAD USING A FULL QUARTER CELL THERMO-ELECTRIC MODEL
USAGE OF A FULL 3D TRANSIENT THERMO-ELECTRIC F.E. MODEL TO STUDY THE THERMAL GRADIENT GENERATED IN THE LINING DURING A COKE PREHEAT
DEVELOPMENT OF A 3D TRANSIENT THERMO-ELECTRIC CATHODE PANEL EROSION MODEL OF AN ALUMINUM REDUCTION CELL
THERMO-ELECTRIC DESIGN OF A 400 kA CELL USING MATHEMATICAL MODELS: A TUTORIAL
DEVELOPMENT OF A 2D+ DYNAMIC MODEL OF AN ALUMINUM REDUCTION CELL
USING ANSYS® BASED ALUMINUM REDUCTION CELL ENERGY BALANCE MODELS TO ASSIST EFFORTS TO INCREASE LAURALCO´S SMELTER PRODUCTIVITY
ANALYSIS SOLUTIONS SPRING 1998: ALUMINUM ELECTROLYSIS PROCESS SIMULATION
COMPUTATION OF ALUMINUM REDUCTION CELL ENERGY BALANCE USING ANSYS® FINITE ELEMENT MODELS
INDUSTRIAL ALUMINUM ELECTROLYSIS TMS COURSE CHARLESTON 1997: PROCESS SIMULATION
SYMPOSIUM ÉLECTROLYSE 1997 CQRDA: OPTIMISATION DU PROCÉDÉ PAR MODÉLISATION
MODELING OF ALUMINUM REDUCTION CELLS USING FINITE ELEMENT ANALYSIS TECHNIQUES
EVALUATION OF THERMAL STRESSES DUE TO COKE PREHEAT OF A HALL-HÉROULT CELL
THERMO-ELECTRO-MAGNETIC MODELING OF A HALL-HÉROULT CELL
THERMO-ELECTRIC ANALYSIS OF THE GRANDE-BAIE ALUMINUM REDUCTION CELL
ANSYS NEWS: ANSYS IN THE ALUMINUM INDUSTRY
THERMAL STUDY OF THE COKE PREHEATING FOR HALL-HÉROULT CELL
THERMO-ELECTRIC ANALYSIS OF ALUMINUM REDUCTION CELLS
THERMO-ELECTRIC COUPLED FIELD ANALYSIS OF ALUMINUM REDUCTION CELLS USING THE ANSYS PARAMETRIC DESIGN LANGUAGE